Search svg image

Mixing Type Air Heaters VZH-S-1.6/VG-S-1.6/VZH-S-2.0/VG-S-2.0/VZH-S-2.5/VG-S-2.5/VZH-S-3.2/VG-S-3.2/VZH-S-4.0/VG-S-4.0

Designation

Mixing type air heaters are designed to heat up to a predetermined temperature (max 120 °C) the air passing through them when burning fuel and mixing combustion products with air, to work with dryers of various efficiency equipped with a vertical channel to supply heated air. Air heaters can operate on the following fuel types: (ZH) diesel fuel, light fuel oil, oil, (G) natural and liquefied gas.

Preferential conditions for sales of equipment of the AMKODOR brand

Our company cooperates with leading companies to provide leasing to purchase special-purpose machines.

Conditions
  • TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is periferal device exhaust (dryer fans)
    • Control method is automatic burner control
    • Rated thermal power, MW is 1.6
    • The volume of pumped heat medium, m3/h is 50 000
    • Fuel consumption is diesel, kg is 149
    • Heat medium temperature, °С is 40-120
    • Burner electric motor power, kW is 5.5
    • Electrical network voltage, V is  220/380
    • Overall dimensions, m are 4.5×1.7×1.95
    • Weight, ton is 1.45
  • schema image
  • VG-S-1.6
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 1.6
    • The volume of pumped heat medium, m3/h is 50 000
    • Fuel consumption is Natural gas, m3 176
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 5.0
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 4.5×1.7×1.95
    • Weight, ton is 1.45

    VZH-S-2.0
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 2.0
    • The volume of pumped heat medium, m3/h is 65 000
    • Fuel consumption is Diesel, kg 186
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 5.5
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 4.95×1.85×2.1
    • Weight, ton is 1.85

    VG-S-2.0
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 2.0
    • The volume of pumped heat medium, m3/h is 65 000
    • Fuel consumption is Natural gas, m3 220
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 5.0
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 4.95×1.85×2.1
    • Weight, ton is 1.85

    VZH-S-2.5
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 2.5
    • The volume of pumped heat medium, m3/h is 80 000
    • Fuel consumption is Diesel, kg 232
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 10.0
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 5.45×2.05×2.35
    • Weight, ton is 2.3

    VG-S-2.5
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 2.5
    • The volume of pumped heat medium, m3/h is 80 000
    • Fuel consumption is Natural gas, m3 275
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 10.5
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 5.45×2.05×2.35
    • Weight, ton is 2.3

    VZH-S-3.2
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 3.2
    • The volume of pumped heat medium, m3/h is 100 000
    • Fuel consumption is Diesel, kg 297
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 10.0
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 6.1×2.35×2.5
    • Weight, ton is 2.5

    VG-S-3.2
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 3.2
    • The volume of pumped heat medium, m3/h is 100 000
    • Fuel consumption is Natural gas, m3 345
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 10.5
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 6.1×2.35×2.5
    • Weight, ton is 2.5

    VZH-S-4.0
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 4.0
    • The volume of pumped heat medium, m3/h is 125 000
    • Fuel consumption is Diesel, kg 371
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 15
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 6.85×2.55×2.7
    • Weight, ton is 3.65

    VG-S-4.0
    TECHNICAL SPECIFICATIONS

    • Heat medium pumping method is Periferal device exhaust (dryer fans)
    • Control method is Automatic burner control
    • Rated thermal power, MW is 4.0
    • The volume of pumped heat medium, m3/h is 125 000
    • Fuel consumption is Natural gas, m3 450
    • Heat medium temperature, °С is 40-120
    • Electric motor burner power, kW is 17
    • Electrical network voltage, V is 220/380
    • Overall dimensions, m are 6.85×2.55×2.7
    • Weight, ton is 3.65

For questions of sale and configuration, please contact dealers in your region

Dilers

For service questions, please contact authorized service centers in your region

Find a service